The engine is rarely why a Weichai diesel generator fails its site acceptance test. In most of the failure reports we review, the cause is one of three specification errors: the l...
READ MOREHigh Reliability: The engine block features a grid structure design for high strength, and the crankshaft is made of high-strength alloy steel with a design life of 32,000 hours.
High Operational Economy: Equipped with large-flow fuel and oil filters as standard, ensuring high filtration precision and providing cleaner fuel and lubricating oil. The filter replacement interval reaches 500 hours, reducing operating costs.
Easy Maintenance: Observation windows are arranged on both sides of the engine body, making it convenient to replace connecting rods and rod bearings.
Technical Parameters
|
Unit power |
800KW |
Engine |
Weichai Power 12M26D902E200 |
||||
|
Generator |
Yangzhou Kangcheng KC800-4 |
|
|
||||
|
Engine: 12M26D902E200 |
Generator: Single bearing, IP22 protection rating, H-class insulation. |
||||||
|
Water tank (40℃), cooling fan with fan safety cover, air filter, fuel filter, oil filter. |
|||||||
|
Shared steel chassis, shock absorbers, standard control panel. |
|||||||
|
24V rechargeable generator, industrial muffler and standard connecting parts. |
|||||||
|
Maintenance-free lead-acid battery and battery connection cables. |
|||||||
|
Voltage level |
|||||||
|
Voltage V |
Frequency Hz |
Number of Phases |
Rated Current A |
Power KW |
Power Factor |
||
|
400/230 |
50 |
3 |
1440 |
800 |
0.8 |
||
|
Engine parameters |
|||||||
|
Manufacturer/Model |
Weichai Power 12M26D902E200 |
||||||
|
Intake System |
Turbocharging + intercooling (turbocharged intercooled) |
||||||
|
Fuel System |
High-pressure common rail |
||||||
|
Number of Cylinders/Arrangement |
12-cylinder/V-type |
||||||
|
Displacement |
31.8L |
||||||
|
Bore * Stroke |
150*150 mm |
||||||
|
Compression Ratio |
15:1 |
||||||
|
Rated Speed |
1500rpm |
||||||
|
Engine Power (Common/Spare) |
8200KW/902KW |
||||||
|
Speed Control System |
Electronic speed control |
||||||
|
Fuel system |
|||||||
|
Backup fuel consumption rate |
225g/kw.h |
||||||
|
Lubrication system |
|||||||
|
Lubricating oil capacity |
113L |
||||||
|
Cooling system |
|||||||
|
Coolant capacity |
203L |
||||||
|
Generator parameters |
|||||||
|
Number of phases |
3 |
||||||
|
Wiring method |
Three-phase four-wire, Y-type interconnection |
||||||
|
Number of bearings |
1 |
||||||
|
Power factor |
0.8 |
||||||
|
Protection class |
IP22 |
||||||
|
Altitude requirement |
≤1000m |
||||||
|
Excitation system |
Brushless self-excited magnet |
||||||
|
Insulation class/Temperature rise class |
H/H |
||||||
|
Telephone impact factor (TIF) |
<50 |
||||||
|
Telephone harmonic factor (THF) |
<2% |
||||||
|
Unit performance parameters |
|||||||
|
Voltage Setting Range |
≥±5% |
||||||
|
Steady-State Voltage Regulation |
≤±1% |
||||||
|
Transient Voltage Deviation (100% Power Drop) |
≤+25% |
||||||
|
Transient Voltage Deviation (Power Increase) |
≤-20% |
||||||
|
Voltage Recovery Time (100% Power Drop) |
≤6S |
||||||
|
Voltage Recovery Time (Power Increase) |
≤6S |
||||||
|
Frequency Setting Range |
0-5% |
||||||
|
Steady-State Frequency Band |
≤1.5% |
||||||
|
Transient Frequency Deviation (100% Power Drop) |
≤+12% |
||||||
|
Transient Frequency Deviation (Power Increase) |
≤-10% |
||||||
|
Frequency Recovery Time (100% Power Drop) |
≤5S |
||||||
|
Frequency Recovery Time (Power Increase) |
≤5S |
||||||
|
Unit Weight |
|
||||||
|
Unit Dimensions |
|||||||












The engine is rarely why a Weichai diesel generator fails its site acceptance test. In most of the failure reports we review, the cause is one of three specification errors: the l...
READ MOREA 400 kW genset ordered on standby rating, then asked to carry a full production shift, usually throws a coolant temperature alarm within three weeks. The mistake repeats every ye...
READ MOREA quotation lands on your desk for a 250 kW standby set: Perkins engine, a name-brand alternator, a 24-hour base tank, a digital controller. The engine badge is the line everyone ...
READ MOREA 400 kW enquiry looks simple until three questions are answered: what is the largest motor on site, how hot does the plant room get in July, and who will service the machine 90 k...
READ MOREA 250 kW set ordered for a garment factory near Dhaka, a 30 kW unit keeping a rural telecom cabinet alive through daily outages, and a 400 kW machine standing behind a hospital's ...
READ MOREEngineering Support Beyond the Generator